CPAP masks and supplies

CPAP Parts Explained: Filters, Tubing, Tubs and Cushions

On this page · 13 sections
  1. What are the main parts of a CPAP machine?
  2. What does the CPAP machine itself do?
  3. What are the parts of a CPAP mask?
  4. Standard vs heated tubing: which do I need?
  5. What does the CPAP filter do, and how often should I change it?
  6. How does the humidifier tub work, and when should I replace it?
  7. Are CPAP parts interchangeable between brands?
  8. What CPAP parts are covered in Canada?
  9. How do I order the right replacement part?
  10. When is a parts problem really a fit or machine problem?
  11. Key takeaways
  12. Frequently asked questions
  13. Sources
Quick answer

A CPAP setup has five main parts. The machine (flow generator) makes the pressure, the humidifier tub adds moisture, the air filter cleans the air coming in, the tubing carries that air to you, and the mask (cushion, frame and headgear) seals it at your face. In Ontario, the ADP-funded system includes the device, a heated humidifier, a basic mask and headgear, a carrying case, 6-foot tubing, the caps and filters needed for setup, and a user manual (ADP manual, 2024). The mask, tubing, filters and tub wear out and need replacing, while public programs fund a new machine about every 5 years.

Most people never think of their CPAP as separate pieces until something leaks, gurgles or smells musty. Knowing what each part does helps you find the problem, reorder the right thing and know what your plan pays for.

This guide walks through every part, what wears out, what Canadian programs cover, and how to order the right replacement.

What are the main parts of a CPAP machine?

Here's the whole system at a glance. The U.S. Medicare column is the most often quoted replacement schedule; it's a payment ceiling, not a medical rule, and most people need far less (see our CPAP replacement schedule).

Part What it does Signs it's worn U.S. Medicare usual maximum
Machine (flow generator) Draws in room air and blows it at your prescribed pressure; records your use Noisy, error messages, less air 5-year useful lifetime
Heated humidifier and water tub Warms and moistens the air Cracks, leaks, a lid that won't seal, scale that won't wash off Water chamber 1 every 6 months
Air filter Traps dust before air enters the machine Visible dirt, discolouration, damage Disposable 2 a month; reusable 1 every 6 months
Tubing (standard or heated) Carries air from the machine to the mask Holes, splits, cracked cuffs, residue you can't wash out 1 every 3 months (either type)
Mask cushion or nasal pillows The soft part that seals against your face Leaks you can't fix by refitting, tears, a stiff or greasy feel Nasal cushion or pillows 2 a month; full face cushion 1 a month
Mask frame Holds the cushion and connects to the tubing; includes the vent Cracks, loose clips, damaged vent Whole mask 1 every 3 months
Headgear Straps that hold the mask on Straps that won't hold their setting 1 every 6 months
Chin strap (optional) Helps keep your mouth closed with a nasal mask Stretched fabric; mouth leaks return 1 every 6 months

Medicare figures: CMS, 2024.

Canadian guidance is plainer. Alberta's sleep apnea pathway says you'll need to replace the mask and tubing every 6 to 12 months "for optimal effect of CPAP therapy," and lists masks, tubing, machine replacements, distilled water and maintenance as ongoing costs (Primary Care Alberta, 2026).

What does the CPAP machine itself do?

The machine, or flow generator, is a quiet blower. It pulls in room air through the filter and pushes it through the humidifier into the tube at your prescribed pressure. Don't change the pressure yourself; comfort settings such as humidity are yours to adjust.

Your machine also records when you use it, and CPAP providers usually send those downloads to your referring doctor (Primary Care Alberta, 2026). Funders often ask for the same data. See CPAP compliance.

How long does the machine last?

Plan on about 5 years. That's when most Canadian programs will fund a new one. Ontario's ADP sets a 5-year minimum funding period for PAP systems (ADP manual, 2024), NIHB funds 1 machine every 5 years (Indigenous Services Canada, 2026), and Saskatchewan's SAIL program treats 5 years as a machine's useful life (Government of Saskatchewan).

Five years is when funding renews, not when a working machine has to go. Alberta's pathway suggests a noisy machine may need upgrading if it's older than 5 years or in poor condition (Primary Care Alberta, 2026).

To be listed by Ontario's ADP, a PAP system must carry at least a 3-year warranty, and ADP pays nothing toward repairs, maintenance or batteries (ADP manual, 2024). Keep your receipt and warranty paperwork where you'll find them.

Read more: When to replace your CPAP machine · How to buy a CPAP

What are the parts of a CPAP mask?

A mask is really three or four parts, and you can often replace them one at a time.

  • Cushion or pillows. The soft part that makes the seal. It wears fastest.
  • Frame. The firmer piece the cushion clips into, with the connection for the tubing.
  • Vent. Every CPAP mask has a small vent that leaks on purpose. It flushes out the air you breathe out so you don't rebreathe it, and machines expect this "intentional" leak and allow for it (ATS, 2013). Never cover or tape over the vent.
  • Headgear. The straps, usually with hook-and-loop tabs or clips. Once the straps stretch, people tighten them to chase leaks, which causes red marks.

Mask styles

Masks come as nasal pillows, nasal masks or cradles, full face (oronasal) masks and hybrids. Specialists writing for the American Academy of Sleep Medicine (AASM) say nasal masks should be considered first-line for most people, and that full face masks are linked to higher leak, lower comfort and lower use. They also recommend fitting masks lying down and cleaning the mask daily to help it seal (AASM, 2026).

The chin strap

If your mouth falls open with a nasal mask, air escapes through your lips and dries your mouth. Alberta's pathway suggests a chin strap for this (Primary Care Alberta, 2026), and the AASM authors say one "could be added" once your pressure is right (AASM, 2026).

Tip: Keep a spare cushion or set of pillows on hand. A tear at 2 a.m. then costs you a few minutes, not a night of therapy, and comparing the old cushion with the new one side by side shows you how much it has changed.

Read more: CPAP masks · Mask types · How to stop CPAP mask leaks · Masks for mouth breathers

Standard vs heated tubing: which do I need?

The U.S. Food and Drug Administration (FDA) describes the tubing simply: a long, flexible hose that connects the machine to the mask so you can move around or turn over in bed (FDA, 2024). There are two kinds.

Standard tubing Heated tubing
How it works Plain plastic hose A heating wire keeps the air warm all the way to the mask
Main benefit Simple and inexpensive Steadier humidity and less condensation in a cold room (Nilius et al., 2018)
Works with Any compatible machine and mask Only the machine (and humidifier) it's designed for
Ontario ADP 6-foot tubing is part of the funded system (ADP manual, 2024) Not listed in the funded system
NIHB 2 a year, with prior approval (Indigenous Services Canada, 2026) Not listed
U.S. Medicare 1 every 3 months 1 every 3 months (CMS, 2024)

Why heated tubing helps in a Canadian winter

Warm, moist air cools as it travels down the tube. If the tube is colder than the air inside it, water condenses out. This is "rainout": gurgling in the tube, drips on your face or a wet cushion.

A German study of 18 people measured mask humidity in bedrooms averaging about 20.7 °C in summer and 14.3 °C in winter. Adding a heated tube kept relative humidity closer to a steady 80% in winter, and the authors recommended a heated tube "to avoid condensation" (Nilius et al., 2018). The study was partly funded by a CPAP maker.

Before you buy heated tubing

You may not need it. A UK hospital sleep service lists cheaper fixes for rainout first: turn the humidity down a notch at a time, put the machine lower than your bed, run a non-heated tube under the bed covers, and turn the bedroom heat up a few degrees (UHB NHS Trust, 2026).

Watch out: Don't add extension hoses to reach a machine across the room. Alberta's pathway allows moving a noisy machine further from the bed but says not to use more than 12 feet of tubing (Primary Care Alberta, 2026).

Read more: CPAP humidifiers and rainout

What does the CPAP filter do, and how often should I change it?

The inlet filter sits where the machine draws in room air. It traps dust, lint and pet hair before they reach the blower and the air you breathe. Machines take a disposable filter, a reusable one, or both, depending on the model.

There's no single Canadian rule for how often to change it. The FDA says air filters "should be replaced or cleaned as often as the manufacturer recommends" (FDA, 2024). For a sense of scale:

  • U.S. Medicare pays for up to 2 disposable filters a month and 1 reusable filter every 6 months (CMS, 2024).
  • NIHB funds up to 14 inlet filters a year, and it's one of the few CPAP supplies that doesn't need prior approval (Indigenous Services Canada, 2026).

Look at the filter weekly and replace it sooner if it looks grey or dirty.

Alberta's pathway lists "wash or replace machine filter" as the fix when the air feels too warm (Primary Care Alberta, 2026), and Saskatchewan's SAIL program won't pay for repairs caused by unchanged filters (Government of Saskatchewan).

How does the humidifier tub work, and when should I replace it?

The humidifier is a small water tub on a heater plate. Air passes over the warmed water and picks up moisture on its way to the tube. A heated humidifier is part of Ontario's funded PAP system (ADP manual, 2024), NIHB's funded machine includes one with a cleanable, reusable water chamber (Indigenous Services Canada, 2026), and Alberta's pathway recommends heated humidity on all CPAP machines (Primary Care Alberta, 2026).

What water to use

Use distilled or demineralized water if you can, which prevents limescale (DRSP Montréal, 2020). One NHS hospital also accepts filtered water, or boiled water that has cooled (UHB NHS Trust, 2026). If your immune system is weakened, Montreal public health advises sterile water only (DRSP Montréal, 2020). Use fresh water every night; reusing the same water raises the risk of respiratory infection (UHB NHS Trust, 2026).

Looking after the tub

  • Empty it every morning and let it dry completely (UHB NHS Trust, 2026).
  • Wash it in warm water with a mild detergent, rinse well and dry away from direct sunlight (UHB NHS Trust, 2026). The FDA says humidifier tanks can be cleaned with mild soap and water as your manual describes (FDA, 2024).
  • Descale with one part household vinegar to ten parts water, if your manual allows it (UHB NHS Trust, 2026).
  • Dishwasher only if your manual says so. One hospital allows its tubs on a delicate or glassware cycle, top shelf only, at no more than 65 °C (UHB NHS Trust, 2026).

When to replace it

Stop using a tub that's cracked or leaking, or has a torn seal (UHB NHS Trust, 2026). A tub that stays cloudy or scaled after descaling is also worth replacing, since you can't clean it properly. U.S. Medicare pays for a new water chamber every 6 months (CMS, 2024), but many reusable tubs last longer with care. In Ontario, ODSP lists replacement water chambers and distilled water among the PAP supplies it can pay for when the ministry approves the need (Government of Ontario, 2026).

Watch out: Empty the tub before you travel, and don't run the humidifier on a plane. One NHS service warns that turbulence may push water into the CPAP unit (UHB NHS Trust, 2026). See travelling with CPAP.

Read more: How to clean your CPAP · CPAP humidifiers

Are CPAP parts interchangeable between brands?

Some are, many aren't, and it's worth checking before you buy.

As a rule of thumb, parts that attach to the machine (water tubs, filters, heated tubes and power supplies) are made for a specific model or family. Cushions fit only their own mask frame and come in several sizes. A plain standard tube is the part most likely to fit more than one setup, but confirm with your supplier.

Heated tubing is the classic mistake: it needs a machine that can power and control it, so one from another brand or model line may not work at all. Check the label on your machine and the markings on your mask, and write down brand, model and size before you shop.

What CPAP parts are covered in Canada?

Less than most people expect. The machine is the part public programs focus on; ongoing supplies are usually on you or your workplace plan.

Program What it pays for parts and supplies
Ontario ADP The first system only: device, heated humidifier, basic mask and headgear, 6-foot tubing and setup filters (ADP manual, 2024). Replacement masks and headgear aren't covered, nor are standalone humidifiers or repairs (Government of Ontario, 2026; ADP manual, 2024)
Ontario ODSP Replacement water chambers and distilled water, on request and with approval (Government of Ontario, 2026)
NIHB (First Nations and Inuit) 2 masks with headgear (by type), 2 sets of nasal pillows, 2 chin straps and 2 standard tubes a year with prior approval; 14 inlet filters a year without. Cleaning systems and cleansers are excluded (Indigenous Services Canada, 2026)
BC Employment and Assistance Accessories and supplies replaced after 1 year, with prior approval; the time limit doesn't apply if your medical condition changes (Government of BC)
Alberta seniors (SNAS) Up to $238 a year for supplies, starting the benefit year after the machine (Government of Alberta)
Saskatchewan SAIL You pay for consumables such as interfaces, tubing and filters; Supplementary Health clients may get them with prior approval (Government of Saskatchewan)

Two details trip people up. NIHB lists whole masks, not cushions; replacement nasal pillows are the only cushion-type item it funds separately (Indigenous Services Canada, 2026). And ADP's mask is basic: upgraded masks and headgear aren't funded, and vendors may bill you the full cost of items outside the funded system (ADP manual, 2024). Details by program: NIHB · Ontario · Alberta.

For most working Canadians, a group or private health plan pays for supplies, often with a yearly limit. See CPAP and extended health benefits, the CPAP tax credit and our coverage checker.

How do I order the right replacement part?

Ten minutes of preparation saves a return trip and a wasted claim.

  1. Identify the machine. Note the brand and exact model from the label.
  2. Identify the mask. Note the mask name, style and cushion size, usually printed on the cushion or frame.
  3. Decide what's actually worn. A leaky mask may need only a new cushion, or new headgear.
  4. Check your coverage. Ask how many items a year your plan pays for, whether cushions are covered alone, and whether you need a new prescription.
  5. Get prior approval if your program needs it. NIHB requires it for most supplies, and BC's program needs approval before you buy (Indigenous Services Canada, 2026; Government of BC).
  6. Order from your clinic or CPAP provider, or a supplier your plan accepts, and ask whether they'll let you try a different size if the new cushion doesn't seal.
  7. Keep itemized receipts for insurance, Alberta's yearly supply claim and your taxes, and note the date each part went into use.

Tip: If a supplier offers automatic shipments, ask them to check with you first. Parts you don't need yet can use up your yearly limit before the part that actually wears out.

When is a parts problem really a fit or machine problem?

Some problems look like worn parts but aren't. Call your clinic or respiratory therapist when:

  • A brand-new cushion leaks as badly as the old one. You may need a different size or style. Alberta's pathway suggests arranging an appointment with your CPAP provider to try another size, accessory or type of mask (Primary Care Alberta, 2026).
  • You still wake with a dry mouth after turning up the humidity. Air is probably escaping through your mouth, which a chin strap or mask change fixes better than more water (Primary Care Alberta, 2026).
  • The machine is noisy. Alberta's pathway suggests first checking hoses, the humidifier, the mask and the connections for leaks; an older or worn machine may need replacing (Primary Care Alberta, 2026).
  • You still feel sleepy despite using CPAP every night.

Don't use ozone or UV "CPAP cleaners" to rescue a part that won't come clean. The FDA warns that "both UV light and ozone can break down CPAP accessories like hoses and masks" (FDA, 2024). Replace the part instead.

Need supplies or a mask refit? Get matched with a clinic →

Key takeaways

  • The cushion wears fastest; Alberta suggests replacing the mask and tubing every 6 to 12 months, and programs usually fund a machine every 5 years.
  • Heated tubing helps with rainout in cold bedrooms, but try lowering the humidity, keeping the machine below the bed and tucking the tube under the covers first.
  • Change the humidifier water daily, use distilled water if you can, and replace a cracked or leaking tub.
  • Tubs, filters and heated tubes are usually model-specific; note your machine and mask models and sizes before ordering.
  • Public programs fund few supplies: Ontario's ADP pays for none after the first system, NIHB funds set quantities, and Alberta seniors get up to $238 a year.

Frequently asked questions

Are CPAP parts universal?

Mostly not. Water tubs, filters and heated tubes are usually made for a specific machine, and cushions fit only their own mask frame. A plain standard tube is the most likely part to fit more than one setup. Check your machine's model and your mask name and size before you buy.

What's the difference between a CPAP cushion and a mask?

The cushion (or set of nasal pillows) is the soft part that seals against your face. The mask is the whole assembly: cushion, frame, vent and usually headgear. Cushions wear faster, so you can often replace just the cushion.

Do I need heated tubing?

Not always. It helps most with water in the tube or mask in a cool bedroom. Try lower humidity, a machine below bed height and a tube under the covers first.

How often should I change my CPAP filter?

Follow your machine's manual. Check it weekly and replace it if it looks dirty. NIHB funds 14 a year without prior approval.

How do I know my tubing needs replacing?

Look for holes, splits, cracked cuffs or residue you can't wash out, or listen for whistling. Alberta's pathway suggests replacing the mask and tubing every 6 to 12 months.

Does OHIP or ADP pay for replacement CPAP parts?

No. ADP funds the first system, including a basic mask, headgear, tubing and setup filters, but not replacement masks, headgear, repairs or standalone humidifiers. ODSP recipients can request replacement water chambers and distilled water.

Can I buy CPAP supplies without a prescription?

Some suppliers sell them, but funders usually need a prescription to pay. NIHB needs a new prescription for every replacement request, and many insurers ask for one too.

Sources

  1. Ontario Ministry of Health. ADP policy and administration manual: respiratory equipment. November 2024.
  2. Government of Ontario. Assistive Devices Program: respiratory equipment and supplies. Updated February 2026.
  3. Government of Ontario. Respiratory supplies: ODSP schedule of benefits for mandatory special necessities. Updated May 2026.
  4. Indigenous Services Canada. NIHB respiratory equipment and supplies benefits list. Modified July 2026.
  5. Government of British Columbia. BCEA policy: medical equipment, breathing devices.
  6. Government of Alberta. Special Needs Assistance for Seniors.
  7. Government of Saskatchewan. Saskatchewan Aids to Independent Living (SAIL) program guide: respiratory equipment.
  8. Primary Care Alberta. Provincial adult obstructive sleep apnea primary care clinical pathway. March 2026.
  9. Centers for Medicare & Medicaid Services. LCD L33718: Positive airway pressure (PAP) devices for the treatment of obstructive sleep apnea. Revision effective January 2024.
  10. U.S. Food and Drug Administration. Do you need a device that claims to clean a CPAP machine? August 2024.
  11. American Academy of Sleep Medicine (Kaminska M, Zielinski D, Adam V). Mask selection for PAP therapy. August 2026.
  12. American Journal of Respiratory and Critical Care Medicine 188(5):613–620, American Thoracic Society (Schwab RJ et al.). An official ATS statement: continuous positive airway pressure adherence tracking systems. September 2013.
  13. Nilius G, Domanski U, Schroeder M, Woehrle H, Graml A, Franke KJ. Nature and Science of Sleep 10:135–142. Mask humidity during CPAP: influence of ambient temperature, heated humidification and heated tubing. 2018.
  14. University Hospitals Birmingham NHS Foundation Trust, Lung Function and Sleep. Humidifier instructions for CPAP. May 2026.
  15. Direction régionale de santé publique de Montréal. Preventing legionellosis at home. July 2020.